All Aluminum Conductor Overhead Power Transmission Cable PVC Insulated or Bare Mv & LV Electric Wires Cables

Product Details
Customization: Available
Application: Overhead, Underground, Industrial, Power Station
Voltage: Low and Medium Voltage Cable
Still deciding? Get samples of US$ 10/Meter
Request Sample
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
10000000 RMB
Plant Area
12000 square meters
  • All Aluminum Conductor Overhead Power Transmission Cable PVC Insulated or Bare Mv & LV Electric Wires Cables
  • All Aluminum Conductor Overhead Power Transmission Cable PVC Insulated or Bare Mv & LV Electric Wires Cables
  • All Aluminum Conductor Overhead Power Transmission Cable PVC Insulated or Bare Mv & LV Electric Wires Cables
  • All Aluminum Conductor Overhead Power Transmission Cable PVC Insulated or Bare Mv & LV Electric Wires Cables
  • All Aluminum Conductor Overhead Power Transmission Cable PVC Insulated or Bare Mv & LV Electric Wires Cables
  • All Aluminum Conductor Overhead Power Transmission Cable PVC Insulated or Bare Mv & LV Electric Wires Cables
Find Similar Products

Basic Info.

Model NO.
AAC 1350
Current
DC Cable
Sheath Material
PVC or None
Material Shape
Round Wire
Certification
ISO, CCC, CE, RoHS, VDE
Model No.
AAC 16-630mm
Range of Application
Power Transmission
Rated Voltage
as Requirment
Tolerance Temperature
-20 Degrees Celsius to 80 Degrees Celsius
Color
Silver or Black Sheadth
Core No.
1 Core
Core Type
Solid
Nominal Cross-Section
16-630mm
Certificats
CCC CE ISO FCC SGS PSE SAA
OEM
Available
ODM
Available
Sample
Available
MOQ
Sample Order/Small Order Can Be Acceptable.
Lead Time
10-15days
Transport
by Sea.
Transport Package
Steel & Wodden Drum
Specification
1.6M*1.6M*1M
Trademark
Qingxin
Origin
China
HS Code
8544492900
Production Capacity
5000km/Month

Product Description

1:APPLICATION:

AAC - The full name: All Aluminum Conductor. It is for stranded 1350 aluminum conductors and is primarily used for overhead transmission and distribution services, where strength of standard ACSR cables is not required. These conductors are used in low, medium and high voltage overhead lines. Class AA for bare conductors used in overhead lines. Class A for conductors to be covered with weather- resistant materials and for bare conductors where greater flexibility is required.

2:CONDUCTORS

Concentric lay stranded conductor consisting of Aluminum Alloy 1350-H19 wires. AAC is available in both single layer and multi-layer constructions.

 

3:STANDARDS:

1.American Standard&Canadian national standards--ASTM B-230 ASTM B-231 

2.British Standards--BS EN 50182/BS 215

3.German Standards--DIN 48201-5

4.International Electrotechnical Commission International Standards&China national standards--IEC 61089 GB/T 1179

5.Australian/New Zealand Standards--AS/NZS 1531-91

6.Russian National Standard--GOST 839-80



4:Parameters
 

ASTM B-230 ASTM B-231 CSA C49

Code

Nominal Area

Stranding

Overall Diameter

Weight

Rated Strength

Electrical Resistance

Current Rating*

 

AWG&MCM

mm^2

No.×mm

mm

kg/km

KN

Ω/Km

A

Peachbell

6

13.3

7/1.56

4.68

36.6

2.53

2.1477

75

Rose

4

21.1

7/1.96

5.88

58.2

3.91

1.3606

99

Iris

2

33.6

7/2.47

7.41

92.6

5.99

0.8567

132

Pansy

1

42.4

7/2.78

8.34

116.6

7.3

0.6763

153

Poppy

1/0

53.5

7/3.12

9.36

147.2

8.84

0.5369

176

Aster

2/0

67.4

7/3.50

10.5

185.7

11.1

0.4267

203

Phlox

3/0

85

7/3.93

11.79

233.9

13.5

0.3384

234

Oxlip

4/0

107.2

7/4.42

13.26

295.2

17

0.2675

270

Valerian

250

126.7

19/2.91

14.55

348.6

20.7

0.2274

299

Sneezewort

250

126.7

7/4.80

14.4

348.8

20.1

0.2269

299

Laurel

266.8

135.2

19/3.01

15.05

372.2

22.1

0.2125

312

Daisy

266.8

135.2

7/4.96

14.88

372.3

21.4

0.2125

311

Peony

300

152

19/3.19

15.95

418.3

24.3

0.1892

335

Tulip

336.4

170.5

19/3.38

16.9

469.5

27.3

0.1686

359

Daffodil

350

177.3

19/3.45

17.25

487.9

28.4

0.1618

369

Canna

397.5

201.4

19/3.67

18.35

554.9

31.6

0.143

397

Goldentuft

450

228

19/3.91

19.55

627.6

35

0.126

429

Syringa

477

241.7

37/2.88

20.16

664.8

38.6

0.1192

444

Cosmos

477

241.7

19/4.02

20.1

664.8

37

0.1192

444

Hyacinth

500

253.3

37/2.95

20.65

696.8

40.5

0.1136

458

Zinnia

500

253.3

19/4.12

20.6

697.1

38.9

0.1134

458

Dahlia

556.5

282

19/4.35

21.75

775.8

43.3

0.1018

489

Mistletoe

556.5

282

37/3.12

21.84

775.7

44.3

0.1016

490

Meadowsweet

600

304

37/3.23

22.61

836.3

47.5

0.0948

511

Orchid

636

322.3

37/3.33

23.31

886.9

50.4

0.0892

530

Heuchera

650

329.4

37/3.37

23.59

907.4

51.7

0.0871

538

Flag

700

354.7

61/2.72

24.48

975.8

57.1

0.0811

561

Varbena

700

354.7

37/3.49

24.43

975.7

55.4

0.0812

561

Nasturtium

715.5

362.6

61/2.75

24.75

998.5

58.4

0.0793

569

Violet

715.5

362.6

37/3.53

24.71

998.5

56.7

0.0794

568

Cattail

750

380

61/2.82

25.38

1046

60.3

0.0754

587

Petunia

750

380

37/3.62

25.34

1046

58.6

0.0755

586

Lilac

795

402.8

61/2.90

26.1

1110

63.8

0.0713

607

Arbutus

795

402.8

37/3.72

26.04

1109

61.8

0.0715

605

Snapdragon

900

456

61/3.09

27.81

1256

70.8

0.0628

654

Cockscomb

900

456

37/3.96

27.72

1256

68.4

0.0631

652

Goldenrod

954

483.4

61/3.18

28.62

1331

75

0.0593

677

Magnolia

954

483.4

37/4.08

28.56

1331

72.6

0.0594

676

Camellia

1000

506.7

61/3.25

29.25

1394

78.3

0.0568

695

Hawkweed

1000

506.7

37/4.18

29.26

1395

76.2

0.0566

696

Larkspur

1033.5

523.7

61/3.31

29.79

1442

81.3

0.0547

710

Bluebell

1033.5

523.7

37/4.25

29.75

1441

78.8

0.0547

710

Marigold

1113

564

61/3.43

30.87

1553

87.3

0.051

740

Hawthorn

1192.5

604.2

61/3.55

31.95

1662

93.5

0.0476

771

Narsissus

1272

644.5

61/3.67

33.03

1774

98.1

0.0445

802

Columbine

1351

694.8

61/3.78

34.02

1884

104

0.042

829

Carnation

1431

725.1

61/3.89

35.01

1997

108

0.0396

858

Gladiolus

1510.5

765.4

61/4.00

36

2108

114

0.0375

885

Coreopsis

1590

805.7

61/4.10

36.9

2216

120

0.0357

911

Jassamine

1750

886.7

61/4.30

38.7

2442

132

0.0324

962

Cowslip

2000

1013

91/3.77

41.47

2787

153

0.0286

1032

Sagebrush

2250

1140

91/3.99

43.89

3166

167

0.0255

1099

Lupine

2500

1267

91/4.21

46.31

3519

186

0.0229

1163

Bitterrot

2750

1393

91/4.42

48.62

3872

205

0.0208

1223

Trillium

3000

1520

127/3.90

50.7

4226

223

0.0193

1271

Bluebonnet

3500

1773

127/4.22

54.86

4977

261

0.0165

1373

 

 

BS EN 50182/BS 215

Code

Nominal Area

Stranding

Overall Diameter

Weight

Rated Strength

Electrical Resistance

Current Rating*

Nominal

Teorical

 

mm^2

mm^2

No.×mm

mm

kg/km

KN

Ω/Km

A

Midge

22

23.33

7/2.06

6.18

64

3.99

1.227

106

Gnat

25

26.8

7/2.21

6.6

73.8

4.83

1.0643

122

Mosquito

35

37.0

7/2.59

7.8

102.1

6.27

0.7749

141

Ladybird

40

42.8

7/2.79

8.4

117.9

7.28

0.6678

157

Ant

50

52.83

7/3.10

9.3

145

8.28

0.5419

175

Fly

60

63.55

7/3.40

10.2

174

9.9

0.4505

196

Bluebottle

70

73.7

7/3.66

11.0

202

11.34

0.3881

215

Earwing

75

78.5

7/3.78

11.4

215

11.94

0.3644

232

Grasshopper

80

84.1

7/3.91

11.7

230

12.78

0.3406

249

Clegg

90

95.6

7/4.17

12.5

262

14.53

0.2944

253

Wasp

100

106

7/4.39

13.17

290

16.00

0.2702

268

Beetle

100

106.0

19/2.67

13.4

293

17.42

0.2704

260

Bee

125

132.0

7/4.90

14.7

361

19.44

0.2169

325

Cricket

150

157.9

7/5.36

16.1

432

23.85

0.1818

345

Hornet

150

157.6

19/3.25

16.25

434

25.7

0.1825

342

Cater.

175

186

19/3.53

17.7

512

28.63

0.1547

399

Chater

200

213.2

19/3.78

18.9

587

35.4

0.1349

412

Spider

225

236.9

19/3.99

20.0

652

36.01

0.1211

462

Cockroach

250

265.7

19/4.22

21.1

731

40.4

0.1083

471

Butterfly

300

322.7

19/4.65

23.25

888

48.75

0.08916

530

Moth

350

373.3

19/5.00

25.0

1027

56.37

0.07711

562

Drone

350

373.3

37/3.58

25.1

1029

57.45

0.07741

560

Locust

400

428.5

19/5.36

26.8

1179

64.73

0.06710

580

Centipede

400

415.2

37/3.78

26.46

1145

63.1

0.06944

616

Maybug

475

486,1

37/4,09

28,6

1342

74.01

0,05900

740

Scorpion

500

529,8

37/4,27

29,9

1460

79.98

0,05400

887

Cicada

600

628,3

37/4,65

32,6

1733

94.95

0,04500

1056

Tarantula

750

794.6

37/5.23

36.6

2191

120.1

0.03627

1320

 

 

DIN 48201-5 

Nominal Area

Stranding

Overall Diameter

Weight

Rated Strength

Electrical Resistance

Current Rating*

Nominal

Teorical

mm^2

mm^2

No.×mm

mm

kg/km

KN

Ω/Km

A

16

15.89

7/1.70

5.1

43

2.84

1.8022

83

25

24.25

7/2.10

6.3

66

4.17

1.181

108

35

34.36

7/2.50

7.5

94

5.78

0.8333

134

50

49.48

7/3.00

9

135

7.94

0.5787

168

50

48.35

19/1.80

9

133

8.45

0.5951

166

70

65.81

19/2.10

10.5

181

11.32

0.4372

200

95

93.27

19/2.50

12.5

256

15.68

0.3085

248

120

116.99

19/2.80

14

322

18.78

0.2459

285

150

147.11

37/2.25

15.8

406

25.3

0.196

328

185

181.62

37/2.50

17.5

500

30.54

0.1588

373

240

242.54

61/2.25

20.3

670

39.51

0.1191

445

300

299.43

61/2.50

22.5

827

47.7

0.0965

506

400

400.14

61/2.89

26

1104

60.86

0.0722

602

500

499.83

61/3.23

29.1

1379

74.67

0.0578

688

625

626.2

91/2.96

32.6

1732

95.25

0.0462

786

800

802.09

91/3.35

36.9

2218

118.39

0.036

907

1000

999.71

91/3.74

41.1

2767

145.76

0.0289

1026

 

 

IEC 61089 GB/T 1179 

Code

Nominal Area

Stranding

Overall Diameter

Weight

Rated Strength

Electrical Resistance

Current Rating*

mm^2

No.×mm

mm

kg/km

KN

Ω/Km

A

10

10

7/1.35

4.05

27.4

1.95

2.8633

62

16

16

7/1.71

5.13

43.8

3.04

1.7896

84

25

25

7/2.13

6.39

68.4

4.5

1.1453

110

40

40

7/2.70

8.1

109.4

6.8

0.7158

147

63

63

7/3.39

10.17

172.3

10.39

0.4545

195

100

100

19/2.59

12.95

274.8

17

0.2877

259

125

125

19/2.89

14.45

343.6

21.25

0.2302

297

160

160

19/3.27

16.35

439.8

26.4

0.1798

345

200

200

19/3.66

18.3

549.7

32

0.1439

396

250

250

19/4.09

20.45

687.1

40

0.1151

454

315

315

37/3.29

23.03

867.9

51.97

0.0916

522

400

400

37/3.71

25.97

1102

64

0.0721

603

450

450

37/3.94

27.58

1239.8

72

0.0641

647

500

500

37/4.15

29.05

1377.6

80

0.0577

688

560

560

37/4.39

30.73

1542.9

89.6

0.0515

736

630

630

61/3.63

32.67

1738.3

100.8

0.0458

789

710

710

61/3.85

34.65

1959.1

113.6

0.0407

845

800

800

61/4.09

36.81

2207.4

128

0.0361

905

900

900

61/4.33

38.97

2483.3

144

0.0321

967

1000

1000

61/4.57

41.13

2759.2

160

0.0289

1026

1120

1120

91/3.96

43.56

3093.5

179.2

0.0258

1091

1250

1250

91/4.18

45.98

3452.6

200

0.0231

1157

1400

1400

91/4.43

48.73

3866.9

224

0.0207

1226

1500

1500

91/4.58

50.38

4143.1

240

0.0193

1270

 

 

AS/NZS 1531-91 

Conductor codename

Stranding and wire diameter

Nominal overall diameter

Cross- sectional area

Approximate mass

Breaking load

Modulus of elasticity

Coefficient of linear expansion

DC resist. at 20°C

AC resist. at 50Hz

 

no/mm

mm

mm2

kg/km

kN

GPa

x 10-6/°C

Ω/km

Ω/km

Leo

7/2.50

7.5

34.4

94.3

5.71

65

23

0.833

1.02

Leonids

7/2.75

8.25

41.6

113

6.72

65

23

0.689

0.842

Libra

7/3.00

9

49.5

135

7.98

65

23

0.579

0.707

Mars

7/3.75

11.3

77.3

211

11.8

65

23

0.37

0.452

Mercury

7/4.50

13.5

111

304

16.9

65

23

0.258

0.315

Moon

7/4.75

14.3

124

339

18.9

65

23

0.232

0.284

Neptune

19/3.25

16.3

158

433

24.7

65

23

0.183

0.224

Orion

19/3.50

17.5

183

503

28.7

65

23

0.157

0.192

Pluto

19/3.75

18.8

210

576

31.9

65

23

0.137

0.168

Saturn

37/3.00

21

262

721

42.2

64

23

0.11

0.135

Sirius

37/3.25

22.8

307

845

48.2

64

23

0.094

0.116

Taurus

19/4.75

23.8

337

924

51.3

65

23

0.0857

0.105

Triton

37/3.75

26.3

409

1120

62.2

64

23

0.0706

0.0872

Uranus

61/3.25

29.3

506

1400

75.2

64

23

0.0572

0.071

Ursula

61/3.50

31.5

587

1620

87.3

64

23

0.0493

0.0616

Venus

61/3.75

33.8

673

1860

97.2

64

23

0.0429

0.0539

 

 

GOST 839-80 Type ACP Wire, Greased All Aluminium Conductor 

Nominal Corss-section

Number of Wires

Wire Diameter

Calculated Cross-section

Overall Diameter

D.C. Resistance at 20

Min. Breaking Load

Conductor Weight

Grease Weight

mm2

 

mm

mm2

mm

Ω/km

 

kg/km

kg/km

10

7

1,35

10,0

4,05

2,8631

1950

27,4

-

16

7

1,70

15,9

5,10

1,8007

3021

43,0

0,5

25

7

2,13

24,9

6,40

1,1498

4500

68,0

0,5

35

7

2,50

34,3

7,50

0,8347

5913

94,0

0,5

40

7

2,70

40,0

8,09

0,7157

6800

109,4

-

50

7

3,00

49,5

9,00

0,5784

8198

135,0

0,5

63

7

3,39

63,0

10,16

0,4544

10390

172,3

-

70

7

3,55

69,3

10,70

0,4131

11288

189,0

1,0

95

7

4,10

92,4

12,30

0,3114

14784

252,0

1,0

100

19

2,59

100,0

12,94

0,2877

17000

274,9

-

120

19

2,80

117,0

14,00

0,2459

19890

321,0

16

125

19

2,89

125,0

14,47

0,2301

21250

343,6

-

150

19

3,15

148,0

15,80

0,1944

24420

406,0

20

160

19

3,27

160,0

16,37

0,1798

26400

439,8

-

185

19

3,50

182,8

17,50

0,1574

29832

502,0

25

200

19

3,66

200,0

18,30

0,1438

32000

549,7

-

240

19

4,00

238,7

20,00

0,1205

38192

655,0

33

250

19

4,09

250,0

20,47

0,1150

40000

687,1

-

300

37

3,15

288,3

22,10

0,1000

47569

794,0

54

315

37

3,29

315,0

23,05

0,0915

51970

867,5

-

350

37

3,45

345,8

24,20

0,0833

57057

952,0

65

400

37

3,66

389,2

25,60

0,0740

63420

1072,0

73

450

37

3,90

449,1

27,30

0,0642

71856

1206,0

84

500

37

4,15

500,4

29,10

0,0576

80000

1378,0

94

550

61

3,37

544,0

30,30

0,0529

89760

1500,0

117

560

37

4,39

560,0

30,73

0,0531

89600

1542,2

-

600

61

3,50

586,8

31,50

0,0491

95632

1618,0

126

630

61

3,63

630,0

32,64

0,0458

100800

1738,4

-

650

61

3,66

641,7

32,90

0,0450

104575

1771,0

138

700

61

3,80

691,7

34,20

0,0417

112725

1902,0

149

710

61

3,85

710,0

34,65

0,0406

113600

1959,2

-

750

61

3,95

747,4

35,60

0,0386

119584

2062,0

161

 

 

GOST 839-80 AAC Conductor, Type a Wire, All Aluminium Conductor

Nominal Corss-section

Number of Wires

Wire Diameter

Calculated Cross-section

Overall Diameter

D.C. Resistance at 20

Min. Breaking Load

Conductor Weight

mm2

 

mm

mm2

mm

Ω/km

 

kg/km

10

7

1,35

10,0

4,05

2,8631

1950

27,4

16

7

1,70

15,9

5,10

1,8007

3021

43,0

25

7

2,13

24,9

6,40

1,1498

4500

68,0

35

7

2,50

34,3

7,50

0,8347

5913

94,0

40

7

2,70

40,0

8,09

0,7157

6800

109,4

50

7

3,00

49,5

9,00

0,5784

8198

135,0

63

7

3,39

63,0

10,16

0,4544

10390

172,3

70

7

3,55

69,3

10,70

0,4131

11288

189,0

95

7

4,10

92,4

12,30

0,3114

14784

252,0

100

19

2,59

100,0

12,94

0,2877

17000

274,9

120

19

2,80

117,0

14,00

0,2459

19890

321,0

125

19

2,89

125,0

14,47

0,2301

21250

343,6

150

19

3,15

148,0

15,80

0,1944

24420

406,0

160

19

3,27

160,0

16,37

0,1798

26400

439,8

185

19

3,50

182,8

17,50

0,1574

29832

502,0

200

19

3,66

200,0

18,30

0,1438

32000

549,7

240

19

4,00

238,7

20,00

0,1205

38192

655,0

250

19

4,09

250,0

20,47

0,1150

40000

687,1

300

37

3,15

288,3

22,10

0,1000

47569

794,0

315

37

3,29

315,0

23,05

0,0915

51970

867,5

350

37

3,45

345,8

24,20

0,0833

57057

952,0

400

37

3,66

389,2

25,60

0,0740

63420

1072,0

450

37

3,90

449,1

27,30

0,0642

71856

1206,0

500

37

4,15

500,4

29,10

0,0576

80000

1378,0

550

61

3,37

544,0

30,30

0,0529

89760

1500,0

560

37

4,39

560,0

30,73

0,0531

89600

1542,2

600

61

3,50

586,8

31,50

0,0491

95632

1618,0

630

61

3,63

630,0

32,64

0,0458

100800

1738,4

650

61

3,66

641,7

32,90

0,0450

104575

1771,0

700

61

3,80

691,7

34,20

0,0417

112725

1902,0

710

61

3,85

710,0

34,65

0,0406

113600

1959,2

750

61

3,95

747,4

35,60

0,0386

119584

2062,0

 

5: Products & factory

 

All Aluminum Conductor Overhead Power Transmission Cable PVC Insulated or Bare Mv & LV Electric Wires Cables
Welcome to Qingdao Dadi Energy Co., Ltd. Our factory was established in 2017,located in Qingdao, China, specializing in manufacturing and selling  wires and cables. We can offer customized service of high and low voltage cross-linked cables, long-life wires and cables, PVC insulated power cables, bare wires, sheathed wires, control cables, shielded cables, halogen-free low smoke wires and cables, rubber sheathed cables, and various types of flame retardant and fire-resistant cables and mineral insulated cables. Our wires and cables have been certified in 28 European countries and exported to over 100 countries and regions, comply with CCC and ISO9001 certificates.  We have remained true to our core principles of customer service, on time delivery, uncompromised quality and exceptional value at competitive prices. Quality assurance, welcome to consult to negotiate!

 

All Aluminum Conductor Overhead Power Transmission Cable PVC Insulated or Bare Mv & LV Electric Wires Cables
All Aluminum Conductor Overhead Power Transmission Cable PVC Insulated or Bare Mv & LV Electric Wires Cables

 
   
All Aluminum Conductor Overhead Power Transmission Cable PVC Insulated or Bare Mv & LV Electric Wires Cables
All Aluminum Conductor Overhead Power Transmission Cable PVC Insulated or Bare Mv & LV Electric Wires Cables
 
All Aluminum Conductor Overhead Power Transmission Cable PVC Insulated or Bare Mv & LV Electric Wires Cables
All Aluminum Conductor Overhead Power Transmission Cable PVC Insulated or Bare Mv & LV Electric Wires Cables
 
All Aluminum Conductor Overhead Power Transmission Cable PVC Insulated or Bare Mv & LV Electric Wires Cables
All Aluminum Conductor Overhead Power Transmission Cable PVC Insulated or Bare Mv & LV Electric Wires Cables





All Aluminum Conductor Overhead Power Transmission Cable PVC Insulated or Bare Mv & LV Electric Wires Cables
6: Production process
All Aluminum Conductor Overhead Power Transmission Cable PVC Insulated or Bare Mv & LV Electric Wires Cables
7:Quality inspection
All Aluminum Conductor Overhead Power Transmission Cable PVC Insulated or Bare Mv & LV Electric Wires Cables

8: Packaging methods
All Aluminum Conductor Overhead Power Transmission Cable PVC Insulated or Bare Mv & LV Electric Wires Cables


Q1:Who you are?  What are your company's Main Products?
 


This is Qingdao dadi energy co., ltd. Our factory was established in 2017,located in Qingdao, China, specializing in manufacturing and selling full series of wires and cables, such as: rubber sheathed flexible cable, sheathed cable, control cable, power cable, aerial insulated cable, aluminum stranded wires and steel core aluminum stranded wires, PVC insulated non-sheathed (soft) wire and cable, special cable.

Q2: How can I get the Quotation of the products?

Pls send your demand or specification to us or just E-mail our trade Manager, We'll reply to you within 2 hours in the Working days.

Q3: What does your company do regarding Quality Control?

Firstly, All raw materials were selected are the highest quality level. Secondly,Professional and skillful workers care for every detail in handling the production. Thirdly, Quality Control Department is specially responsible for quality checking in each process and final check before shipping to our customers.

Q4: I didn't find my needed model in this page. Do you provide OEM Project Service?
 
Surely , our factory could manufacturing more than10000 models, OEM & ODM order is warmly welcome and we can you put your brand name, (logo) on these products. What's more, our R&D team will give you professional suggestions.

Q5: How could I get the Sample?

We are honored to offer you samples if we have it in stock, usually it is not free , but we will return it to your on first time mass order .but you need to pay the freight. If you have a courier account or forwarder in China, we can send it your courier to collect samples.

Q6: How long is the Delivery Time?

For Sample: 1-3 working days ; For small orders: 3-10 working days; For mass orders: 10-18 working days. It is better to communicate with us if you are interested to place an order. It depends on your order quantity.

Q7: What are your payment terms?

Our payment term is usually T/T 30% in advanced, the balance before picking up the goods or L/C at sight.

Q8: What is your Warranty? How about MOQ ?

All the products will have 24 months Warranty,Our company has MOQ requirement, but we also accept small quantity. We would love to grow up with every customers. Please feel free to contact us and send us your inquiry.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier