Customization: | Available |
---|---|
Application: | Construction, Overhead, Underground, Industrial, Power Station |
Voltage: | Low and Medium Voltage Cable |
Still deciding? Get samples of US$ 10/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
IEC 60502-1 cables are used for electricity supply in low voltage installation system, IEC 60502-1 cables are
suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations,
local energy distributions, industrial plants, where there is no risk of mechanical damage.
Conductors:
Copper or Aluminium conductor, round standed or Shaped, Class 2 to IEC 60228, BS EN 60228. For smaller
sizes, a solid round conductor, Class 1 as per IEC 60228, BS EN 60228 can also be supplied upon request.
Insulation:
PVC Insulation material and thickness shall be as per IEC 60502-1 and BS 6346.
PVC material shall be Type A as per IEC 60502-1 or TI1 as per BS EN 50363.
PVC Insulation material as per SASO 1694 rated for 85°C continuous operation is also available upon special
request.
Assembly/Inner Sheath :Two, Three or Four insulated conductors are laid-up together with non-hygroscopic
fillers and the assembly is bedded with an extruded layer of PVC. In case of non armoured cables, this layer may
be omitted .
Armour :Aluminum/Galvanized Steel Wires applied helically over the bedding as per IEC 60502 or as per BS
5467, BS 6346. Single core cables shall be Aluminium wire armour. Aluminum/Steel Tapes applied helically over
the bedding of multi-core cables as per IEC 60502.
Outer Sheath:Outer sheath shall be of Extruded PVC Type ST2 as per IEC 60502-1 or Type 9 as BS 6346/5467.
Special type of PVC sheathing material such as Fire Retardant PVC, Anti-Termite PVC, Anti-Rodent PVC,
Sunlight resistant PVC, Oil Resistant PVC are available on special request. Also, special sheathing materials such
as LLDPE, MDPE, HDPE, LSF, CPE are available on request.
Fire Performance of Cable Sheaths :Cables can be supplied with special flame retardant PVC outer sheath to
comply with the flame test requirements of IEC 60332-3-22, IEC 60332-3-23 and IEC 60332-3-24, can also
supply cables with Low Smoke Halogen Free (LSHF) material according to IEC 60502-1, BS 7211, BS 6724 or
other equivalent standards.
Model |
Name |
Application site |
Section area |
Cores |
Rate voltag |
VV |
Copper Conductor PVC insulated PVC sheathed power cable |
Indoors, in tunnel or cable trench, unable to bear external mechanical forces. Single-core cables laid in magnetic ducts are not allowed . |
10 16 25 35 50 70 95 120 150 185 240 300 400 |
1 2 3 4 5 3+1 4+1 3+2 |
0.6/1kv 8.7/15kv 12/20kv 18/30kv 21/35kv |
VLV |
Aluminum Conductor PVC insulated PVC sheathed power cable |
||||
YJV |
Copper Conductor XLPE insulated PVC sheathed power cable |
||||
YJLV |
Aluminum Conductor XLPE insulated PVC sheathed power cable |
||||
YJY |
Copper Conductor XLPE insulated PE sheathed power cable |
||||
YJLY |
Aluminum Conductor XLPE insulated PE sheathed power cable |
||||
VV23 |
Copper Conductor PVC insulated steel wire armored PVC sheathed power cable |
Indoor, tunnel, cable trench or underground laying, able to bear external mechanical forces, but can not afford a big pull. |
|||
VLV22 |
Aluminum Conductor PVC insulated steel tape armored PVC sheathed power cable |
||||
YJV22 |
Copper Conductor XLPE insulated steel tape armored PVC sheathed power cable |
||||
YJLV22 |
Aluminum Conductor XLPE insulated steel tape armored PVC sheathed power cable |
||||
YJV23 |
Copper Conductor XLPE insulated steel tape armored PE sheathed power cable |
||||
YJLV23 |
Aluminum Conductor XLPE insulated steel tape armored PE sheathed power cable |
||||
VV32 |
Copper Conductor PVC insulated steel wire armored PVC sheathed power cable |
Indoors, in tunnel, cable trench, well or burying, able to bear external mechanical forces and a certain tension. |
|||
VLV32 |
Aluminum Conductor PVC insulated steel wire armored PVC sheathed power cable |
||||
YJV32 |
Copper Conductor XLPE insulated steel wire armored PVC sheathed power cable |
||||
YJLV32 |
Aluminum Conductor XLPE insulated steel wire armored PVC sheathed power cable |
||||
YJV33 |
Copper Conductor XLPE insulated steel wire armored PE sheathed power cable |
||||
YJLV33 |
Aluminum Conductor XLPE insulated steel wire armored PE sheathed power cable |
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation thickness | Nominal Inner Covering thickness | Nominal Alum Wire dia. | Nominal Sheath thickness | Overall Diameter (Approx.) |
---|---|---|---|---|---|---|
mm² | mm | mm | mm | mm | mm | mm |
1x4 | 2.3 | 1 | 1 | 0.8 | 1.8 | 11.5 |
1x6 | 2.8 | 1 | 1 | 0.8 | 1.8 | 12 |
1x10 | 3.6 | 1 | 1 | 0.8 | 1.8 | 12.8 |
1x16 | 4.5 | 1 | 1 | 0.8 | 1.8 | 13.7 |
1x25 | 5.6 | 1.2 | 1 | 0.8 | 1.8 | 15.2 |
1x35 | 6.7 | 1.2 | 1 | 1.25 | 1.8 | 17.2 |
1x50 | 8 | 1.4 | 1 | 1.25 | 1.8 | 18.9 |
1x70 | 9.4 | 1.4 | 1 | 1.25 | 1.8 | 20.3 |
1x95 | 11 | 1.6 | 1 | 1.6 | 1.8 | 23 |
1x120 | 12.4 | 1.6 | 1 | 1.6 | 1.8 | 24.4 |
1x150 | 13.8 | 1.8 | 1 | 1.6 | 1.8 | 26.2 |
1x185 | 15.3 | 2 | 1 | 1.6 | 1.9 | 28.2 |
1x240 | 17.5 | 2.2 | 1 | 1.6 | 1.9 | 31 |
1x300 | 19.5 | 2.4 | 1 | 2 | 2.1 | 34.4 |
1x400 | 22.6 | 2.6 | 1.2 | 2 | 2.2 | 38.6 |
1x500 | 25.2 | 2.8 | 1.2 | 2 | 2.3 | 41.8 |
1x630 | 28.3 | 2.8 | 1.2 | 2.5 | 2.4 | 46.2 |
Two cores(Galvanized steel wire armoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation thickness | Nominal Inner Covering thickness | Nominal Steel Wire dia. | Nominal Sheath thickness | Overall Diameter (Approx.) |
---|---|---|---|---|---|---|
mm² | mm | mm | mm | mm | mm | mm |
2x2.5 | 1.8 | 0.8 | 1 | 0.8 | 1.8 | 14 |
2x4 | 2.3 | 1 | 1 | 1.25 | 1.8 | 16.7 |
2x6 | 2.8 | 1 | 1 | 1.25 | 1.8 | 17.7 |
2x10 | 3.6 | 1 | 1 | 1.25 | 1.8 | 19.3 |
2x16 | 4.5 | 1 | 1 | 1.25 | 1.8 | 21.1 |
2x25 | 5.6 | 1.2 | 1 | 1.6 | 1.8 | 24.8 |
2x35 | 6.7 | 1.2 | 1 | 1.6 | 1.8 | 27 |
2x50 | 8 | 1.4 | 1 | 1.6 | 1.9 | 30.7 |
2x70 | 9.4 | 1.4 | 1 | 2 | 2.1 | 34.5 |
2x95 | 11 | 1.6 | 1.2 | 2 | 2.2 | 39.2 |
2x120 | 12.4 | 1.6 | 1.2 | 2 | 2.3 | 42.2 |
2x150 | 13.8 | 1.8 | 1.2 | 2.5 | 2.5 | 47.2 |
2x185 | 15.3 | 2 | 1.4 | 2.5 | 2.6 | 51.6 |
2x240 | 17.5 | 2.2 | 1.4 | 2.5 | 2.8 | 57.2 |
2x300 | 19.5 | 2.4 | 1.6 | 2.5 | 3 | 62.8 |
2x400 | 22.6 | 2.6 | 1.6 | 2.5 | 3.2 | 70.3 |
Three cores(Galvanized steel wire armoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation thickness | Nominal Inner Covering thickness | Nominal Steel Wire dia. | Nominal Sheath thickness | Overall Diameter (Approx.) |
---|---|---|---|---|---|---|
mm² | mm | mm | mm | mm | mm | mm |
3x2.5 | 1.8 | 0.8 | 1 | 0.8 | 1.8 | 14.5 |
3x4 | 2.3 | 1 | 1 | 1.25 | 1.8 | 17.4 |
3x6 | 2.8 | 1 | 1 | 1.25 | 1.8 | 18.4 |
3x10 | 3.6 | 1 | 1 | 1.25 | 1.8 | 20.2 |
3x16 | 4.5 | 1 | 1 | 1.6 | 1.8 | 22.8 |
3x25 | 5.6 | 1.2 | 1 | 1.6 | 1.8 | 26 |
3x35 | 6.7 | 1.2 | 1 | 1.6 | 1.9 | 28.5 |
3x50 | 8 | 1.4 | 1 | 2 | 2 | 33.3 |
3x70 | 9.4 | 1.4 | 1.2 | 2 | 2.1 | 37 |
3x95 | 11 | 1.6 | 1.2 | 2 | 2.3 | 41.6 |
3x120 | 12.4 | 1.6 | 1.2 | 2.5 | 2.4 | 45.9 |
3x150 | 13.8 | 1.8 | 1.4 | 2.5 | 2.6 | 50.4 |
3x185 | 15.3 | 2 | 1.4 | 2.5 | 2.7 | 54.8 |
3x240 | 17.5 | 2.2 | 1.5 | 2.5 | 2.9 | 61.2 |
3x300 | 19.5 | 2.4 | 1.6 | 2.5 | 3.1 | 66.8 |
3x400 | 22.6 | 2.8 | 1.6 | 3.15 | 3.4 | 76.7 |
3x500 | 25.2 | 2.8 | 1.8 | 3.15 | 3.7 | 83.6 |
Three cores+1(Galvanized steel wire armoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation thickness | Nominal Inner Covering thickness | Nominal Steel Wire dia. | Nominal Sheath thickness | Overall Diameter (Approx.) | ||
---|---|---|---|---|---|---|---|---|
mm² | mm | mm | mm | mm | mm | mm | mm | mm |
3x10 +6 | 3.6 | 2.8 | 1 | 1 | 1 | 1.25 | 1.8 | 21.9 |
3x16 +10 | 4.5 | 3.6 | 1 | 1 | 1 | 1.6 | 1.8 | 24.2 |
3x25 +16 | 5.6 | 4.5 | 1.2 | 1 | 1 | 1.6 | 1.8 | 27.9 |
3x35 +16 | 6.7 | 4.5 | 1.2 | 1 | 1 | 1.6 | 1.9 | 30.8 |
3x50 +25 | 8 | 5.6 | 1.4 | 1.2 | 1 | 2 | 2 | 36.4 |
3x70 +35 | 9.4 | 6.7 | 1.4 | 1.2 | 1.2 | 2 | 2.1 | 40.1 |
3x95 +50 | 11 | 8 | 1.6 | 1.4 | 1.2 | 2.5 | 2.3 | 46.3 |
3x120 +70 | 12.4 | 9.4 | 1.6 | 1.4 | 1.4 | 2.5 | 2.4 | 50.3 |
3x150 +70 | 13.8 | 9.4 | 1.8 | 1.4 | 1.4 | 2.5 | 2.6 | 55 |
3x185 +95 | 15.3 | 11 | 2 | 1.6 | 1.4 | 2.5 | 2.7 | 60.3 |
3x240 +120 | 17.5 | 12.4 | 2.2 | 1.6 | 1.6 | 2.5 | 2.9 | 67 |
3x300 +150 | 19.5 | 13.8 | 2.4 | 1.8 | 1.6 | 3.15 | 3.1 | 74.6 |
3x400 +185 | 22.6 | 15.3 | 2.6 | 2 | 1.8 | 3.15 | 3.4 | 84.1 |
3x500 +240 | 25.2 | 17.5 | 2.8 | 2.2 | 2 | 3.15 | 3.7 | 91.8 |
Four cores(Galvanized steel wire armoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation thickness | Nominal Inner Covering thickness | Nominal Steel Wire dia. | Nominal Sheath thickness | Overall Diameter (Approx.) |
---|---|---|---|---|---|---|
mm² | mm | mm | mm | mm | mm | mm |
4x4 | 2.3 | 1 | 1 | 1.25 | 1.8 | 18.5 |
4x6 | 2.8 | 1 | 1 | 1.25 | 1.8 | 19.7 |
4x10 | 3.6 | 1 | 1 | 1.25 | 1.8 | 22.3 |
4x16 | 4.5 | 1 | 1 | 1.6 | 1.8 | 24.5 |
4x25 | 5.6 | 1.2 | 1 | 1.6 | 1.9 | 28.2 |
4x35 | 6.7 | 1.2 | 1 | 1.6 | 2 | 31.1 |
4x50 | 8 | 1.4 | 1 | 2 | 2.1 | 36.7 |
4x70 | 9.4 | 1.4 | 1.2 | 2 | 2.3 | 40.4 |
4x95 | 11 | 1.6 | 1.2 | 2.5 | 2.5 | 46.6 |
4x120 | 12.4 | 1.6 | 1.4 | 2.5 | 2.6 | 50.6 |
4x150 | 13.8 | 1.8 | 1.4 | 2.5 | 2.7 | 55.3 |
4x185 | 15.3 | 2 | 1.4 | 2.5 | 2.9 | 60.6 |
4x240 | 17.5 | 2.2 | 1.6 | 2.5 | 3.1 | 67.3 |
4x300 | 19.5 | 2.4 | 1.6 | 3.15 | 3.4 | 74.9 |
4x400 | 22.6 | 2.6 | 1.8 | 3.15 | 3.7 | 84.4 |
4x500 | 25.2 | 2.8 | 2 | 3.15 | 3.9 | 92.1 |